| INPUT | |
|---|---|
| Voltage Range | 230V AC ± 10% |
| Frequency Range | 50Hz, Single Phase |
| Power Factor | 0.95/230VAC at full load |
| Efficiency | 95% |
| OUTPUT - SINGLE CHANNEL | |
| DC Voltage | 0 to 300V (Variable) |
| Rated Current | 0 to 10A (Variable) |
| TECHNICAL SPECIFICATION | |
| PROTECTION Overload / Short Circuit |
Ripple & Noise <10mVrms |
| Operating Temperature 0°C - 50°C |
Storage Temperature 0°C to 65°C |
| Regulation CV Mode Line & Load regulation better than ±0.05% |
Regulation CC Mode Line & Load regulation better than ±0.1% |
| Stability After 8Hrs 0.05% ±5mV |
Transient Recovery 50μs |
| Indications: 3-Digit LED Digital meters for Voltage & Current, Accuracy: ±0.5% ±2 Counts |
Output Control: Coarse and Fine single-turn Potentiometers for V & I |
| FEATURES | |
| Good Regulation | Low Ripple & Noise |
| Constant Voltage/Current limited | Continuously Variable Voltage |
| Continuously Variable maximum Current limit from 10% to 110% of full load | Electrically Floating output. Can be floated up to 300V off ground |
| LED indication for O.L. | Soft start Circuit |
| Accessories: User Manual with Warranty Certificate & Q.C.C. Test report. | |
| RUGGED AND AESTHETIC MECHANICAL AND ELECTRICAL DESIGN | |